Skip to content
Prev 371514 / 398506 Next

gsDesign Pocock & OBF boundary

Sorry it didn 't work again. I am on yahoo mail, and just found a switch to change from Rick text to Plain text, so here it goes again:


I am learning to use the gsDesign package. 

I have a question about Pocock and OBF boundary. As far as I can understand, these 2 boundaries require equal spacing between interim analyses (maybe this is not correct?). But looks like I can still use gsDesign to run an analysis based on unequal spacing:
Symmetric two-sided group sequential design with 
90 % power and 5 % Type I Error. 
Spending computations assume trial stops 
if a bound is crossed. 

         Sample 
         Size 
Analysis Ratio*  Z   Nominal p  Spend 
       1  0.796  1.82   0.0346 0.0346 
       2  1.061  1.82   0.0346 0.0154 
   Total                      0.0500 

++ alpha spending: 
Pocock boundary. 
* Sample size ratio compared to fixed design with no interim 
  

Can anyone share some light whether the above analysis is still valid? Or for unequal spacing, I have to use Lan-Demet?s error spending function approximations? Thank you,